Devices, calibration and meter check
Meter statuses on the Devices screen, offline and error alerts, the calibration reminder and checking meter accuracy with a manual measurement.
The installation team fits and sets up the meters; you watch their status on the Devices screen. This article covers the devices screen, the calibration reminder and checking a meter with a manual measurement.
Who installs the meters?
The installation team defines the milking area, unit and milking point layout, and which meter is fitted to which point. In the app and the web panel:
- there is no meter pairing or adding (code, QR),
- a meter cannot be renamed, moved to another point or deleted,
- areas, units or points cannot be added,
- the calibration factor cannot be changed and the firmware cannot be updated.
A wrongly fitted meter would write its data to another point, so these tasks stay with the installation team. To add, move or calibrate a meter, talk to the installation team.
Devices screen
- Web panel: Devices in the left menu
- Mobile app: the Devices tab at the bottom
Summary counts appear at the top: Online (green), Offline (red), and, if any, Points without meter and Meters without profile. A meter without a profile is in quarantine; its data is not processed. Let the installation team know.
Below that, the layout is listed as a tree: area, the units inside it, and the points inside each unit. The unit header shows the number of points and either "all online" or how many points need attention. Units with problems open expanded; units without problems open collapsed. The screen refreshes every minute.
The Meters not installed section shows spare meters that are not attached to a point; these are not faults.
Point statuses
- No meter installed (grey): there is no meter at the point.
- Reported an error (yellow): the meter reported an error in the last 24 hours; the error code and time are shown.
- Calibration due (yellow): the next calibration date has arrived.
- Online (green): no problem; the last seen time is shown.
- Offline (red): nothing has been heard from the meter for a while.
A green row can also carry a yellow note: Low flow (the point reads noticeably lower than the other points of its unit) or Check deviation (manual measurements deviate from the meter).
If nothing is heard from a meter for 5 minutes, it counts as offline; as soon as data comes in again, it is online again. If a meter goes offline during an open milking, you get a "meter offline, no milking data coming in" alert. If the power goes off outside milking, no alert is sent.
Device details
Click a row to open its details: serial number, profile, protocol, firmware version, calibration factor, last and next calibration, last seen and last error. The information is display only.
Point reading low flow
If a point's average flow rate over the last 7 days is below 70% of the median of the other points in the same unit, the point counts as "low" and a Milking point reads low flow alert is created. For this, the point needs at least 10 milkings and 3 different animals, and the unit needs at least 2 other points. The details show the advice "Check the cluster, pulsator and milk hose." When the situation is fixed, the alert closes by itself.
Calibration
The installation team does the calibration and enters its date; the interval defaults to 180 days. In the details you see Calibration factor, Last calibration and Next calibration. If no date has been entered, it says "No record (entered by the installation team)" and no reminder comes.
When the next calibration date arrives, the row turns into a yellow Calibration due, a Calibration due alert is created, and the details say "due now, call the installation team". Once the meter is calibrated again, the alert closes.
Checking the meter with a manual measurement
You can check whether a meter measures correctly by weighing or measuring the milk of one milking and comparing it with the meter. The app never changes the factor. The farm owner and operators can do this.
- Open the animal's page (web: Animals; mobile: History → Animals).
- In the Recent milkings list, click a finished milking. A milking in progress cannot be selected.
- The Manual measurement window shows the amount the meter measured. Weigh or measure the milk from this milking.
- Enter it in the Measured milk field in your farm's unit (L or kg) and save.
The result shows the deviation for this milking and the average of the meter's recent checks. One check is kept per milking; if you enter it again, it is updated. The average is calculated from the last 10 checks within the last 90 days.
If there are at least 3 checks and the average deviation is above 5%:
- the result says "The deviation persists: ask the installation team for calibration.",
- a yellow Check deviation shows on the device row,
- a Meter drift alert is created.
When the average drops below the limit, the alert closes. The Meter check section in the device details lists the average and the last three checks.
Did not find what you were looking for?
Every topic is in the help center. If you still have a question, write to us from Settings → Feedback in the app or the panel.
Milking and devices: more articles
Live milking
Starting and ending a milking session, point cards and colours, the red alert sound, assigning animals and bulk pairing with Confirm group as is.
Read the articleMilking parlor tablet (kiosk mode)
Opening a separate account for the shared parlor tablet; only the live milking screen on the tablet, what the tablet can do, and signing out.
Read the article