Milking and devices

Live milking

Starting and ending a milking session, point cards and colours, the red alert sound, assigning animals and bulk pairing with Confirm group as is.

The live milking screen shows the current flow rate and yield of every milking point while milking is in progress. You start milking, assign animals and end milking from this screen.

Where is the screen?

  • Web panel: Live milking in the left menu. If more than one milking is open, area and milking type tabs appear at the top.
  • Mobile app: the Live tab at the bottom. You choose the area from the list at the top.

In the web panel, starting and ending milking and assigning animals are open to the farm owner and the operator; the viewer can only watch.

How does a milking session open?

The session opens by itself: when there is no open session and a connected meter reports flow. The milking type is set by the time of day: 04:00–12:00 Morning, 14:00–22:00 Evening, other hours Other. These sessions show "opened automatically".

Starting manually is optional:

  1. Press Start milking.
  2. In the web panel, choose the Milking area.
  3. Choose the Milking type: Morning, Evening or Other.
  4. Press Start.

Only one session can be open in an area at a time. If no flow arrives for 45 minutes, the session closes by itself.

Milking point card

Each card shows:

  • The unit and point number, and a dot in the flow rate colour.
  • The name or ear tag of the assigned animal. If there is no animal, it shows No animal assigned; if the ear tag read by RFID is not registered, it shows Unknown tag.
  • For an animal in its withdrawal period, a red Withhold milk · withdrawal {date}.
  • The current flow rate (L/min).
  • The yield bar: what percentage of the expected amount has been milked, with the current and target amounts.
  • Status: Idle, Milking, Done or Error.

At the top you see the number of active and idle points, and the start and last update times. If there is a connection problem, it shows "Connection problem · last data {time}".

What do the colours mean?

Flow rate (the dot on the card):

  • Green: flow rate above the upper threshold.
  • Yellow: flow rate between the lower and upper thresholds.
  • Red: flow rate below the lower threshold; it shows Low flow.
  • Grey: no flow, no animal assigned, or the meter is offline.

During the warm-up time at the start of milking, and after 85% of the expected amount has been milked, red is not shown; it stays yellow. If red lasts as long as the alert delay in the threshold settings, a Low flow rate notification is sent; once per animal per session.

Yield bar:

  • Green: 90% of the expected amount or more.
  • Yellow: 60–90%.
  • Red: below 60%.
  • Grey: no expected amount (No target).

The expected amount is the animal's average for the same milking type over the last 7 days; if it has no history, the value in the species' threshold settings is used. To change the thresholds, see thresholds and alerts.

Red alert sound

When a point being milked turns red, the screen alerts you: on mobile, vibration and an alert sound; in the web panel, a two-tone beep, vibration on devices that support it, and a short flash on the card. It plays once per point and animal; points that are already red when the screen opens do not play.

  • Use the bell icon in the top bar to Turn off red alert / Turn on red alert. It is on by default; your choice is saved on the device.
  • The browser plays the sound only after you have clicked the page or pressed a key once.
  • No sound plays while the app is closed or in the background; phone notifications cover that.

Assigning an animal

If there is an RFID reader, assignment happens by itself. If not:

  1. Click the point's card.
  2. In the list that opens, search by Ear tag, name or RFID. If the herd has more than one dairy species, a species choice appears.
  3. Choose the animal.

Only milking animals are listed. The list comes in this order:

  1. Suggestions based on the order of previous milkings ("Usually follows {tag}")
  2. The animal that was at this point in the previous milking
  3. Animals milked in the previous milking
  4. The others, in ear tag order
  5. Animals at another point, at the very bottom and not selectable

An animal in its withdrawal period can be chosen and appears with the Withhold milk label.

If you choose another animal at a point where measuring has already started, you are asked Was the previous animal milked?:

  • Milked: the milk is credited to the previous animal.
  • Wrong assignment: the measurement is deleted and the new animal is assigned.

You can undo a wrongly assigned animal with Remove assignment; the measurement from this milking is deleted and not credited to any animal. This cannot be undone.

Confirm group as is

On farms without an RFID reader, this fills the empty points in one go, following the entry order of previous milkings. The suggestions are calculated from the area's last 10 milkings.

  1. Press Confirm group as is. The button appears while a session is open, at least one point is empty and there are suggestions.
  2. Check the suggested point → animal list.
  3. Confirm with Pair all (Confirm on mobile).

You can change a wrong one later by clicking the point. Points that cannot be assigned are skipped and noted in the result.

Ending milking

Press End milking and confirm. Open animal milkings are closed and the session summary is calculated; this cannot be undone. A single animal's milking also closes by itself when the flow rate stays below the end flow rate threshold for the wait time.

For the summary of an ended session, see yield report and milking history.

Did not find what you were looking for?